The CG Generators offer the purest source ofcalibration gas for your CO2 Analyzer, ensuring the cleanest possible starting point for emissions measurement, monitoring and analysis.
TECHNICAL SPECIFICATIONS
Max Outlet Flow: 15 - 22 L/min
Pressure Point: -70C / -94F
Required Inlet Air Pressure: 4-8 bar
Required Inlet Flow @ rated O/P 27 L/min: 44 L/min
Warm Up time for spec. THC: 30 mins
Gas Outlets: 1/4
Electrical Requirements:
CG15L - 220v 5.0A / 120v 4.5A
CG22L - 220v 8.8A / 120v 9.5A
Dimensions WxDxH:
CG15L - 62 x 43 x 41 cm/ 24 x 17 x 16 ins
CG22L - 88 x 43 x 41 cm/ 35 x 17 x 16 ins
The CG Range Calibration Gas Cylinder is developed to support a broad spectrum of sectors, including laboratory analysis, industrial safety protocols, medical testing, and environmental monitoring. Its customizable composition and compatibility with CGA or BS valves make it suitable for diverse equipment and applications.
Manufactured from high-quality aluminium or steel, the CG Range cylinder is designed for durability and safety under pressures up to 150 bar. Its robust build paired with core components like precision valves and regulators ensures longevity and optimal performance during manual operation.
FAQs of CG RANGE CALIBRATION GAS RANGE:
Q: How do I use the CG Range Calibration Gas Cylinder for instrument calibration?
A: Connect the calibration gas cylinder to your instrument using the appropriate regulator and valve type (CGA or BS, as specified). Follow manufacturer guidelines to release the gas steadily for accurate calibration of your analytical or detection equipment.
Q: What are the storage recommendations for this calibration gas cylinder?
A: Store the cylinder in a cool, dry, and well-ventilated location. Avoid exposure to direct sunlight or extreme temperatures to preserve gas quality and maintain the maximum shelf life of 36 months.
Q: When should I replace or reorder a calibration gas cylinder?
A: Replace or reorder the cylinder before the shelf life expires (maximum 36 months) or when the gas pressure drops below the necessary calibration requirement. Regular checks ensure reliable performance and safety.
Q: Where can the CG Range Calibration Gas Cylinder be utilized?
A: This cylinder is ideal for use in laboratories, industrial safety installations, medical settings, and environmental monitoring stations. Its flexible composition makes it suitable for a wide range of calibration and gas detection instruments.
Q: What is the process for customizing the gas composition in the CG Range cylinder?
A: Upon ordering, specify your calibration requirements so that the manufacturer can blend the gas composition accordingly. This ensures your cylinder provides precise calibration standards tailored to your equipment or industry needs.
Q: What benefits does manual operation offer for this calibration gas cylinder?
A: Manual operation allows for straightforward setup and usage, offering the user direct control over the calibration process and enhancing reliability by reducing risks associated with automation or power failures.
Q: What factors affect the weight and dimensions of the cylinder?
A: The cylinders weight and dimensions vary depending on the selected gas volume and required pressure rating. Choose the appropriate size based on your calibration frequency and equipment compatibility requirements.