08045815658
info@nationalsales.co
Change Language
Air-sampler System Mas-100 Nt

Air-sampler System Mas-100 Nt

Product Details:

  • Automation Grade Semi-automatic
  • Core Components Perforated Lid, Impeller, Control Unit
  • Frequency 50/60 Hz
  • Power Source NiMH Rechargeable Battery Pack
  • Temperature Range +10C to +40C
  • Model No MAS-100 NT
  • Voltage 100-240 V AC
  • Click to view more
X

Air-sampler System Mas-100 Nt Price And Quantity

  • 100 INR
  • 1 Number

Air-sampler System Mas-100 Nt Product Specifications

  • Approx. 2 kg
  • Semi-automatic
  • Digital Display
  • Perforated Lid, Impeller, Control Unit
  • 50/60 Hz
  • NiMH Rechargeable Battery Pack
  • +10C to +40C
  • MAS-100 NT
  • Active Air Sampler
  • 135mm 135mm 130mm
  • 100-240 V AC
  • Microbiological Air Monitoring
  • 2% at set flow rate
  • Validated for ISO 14698, Portable, Battery Operated
  • Stainless Steel Housing
  • 0-99,999 Liters
  • 100 liters/minute

Air-sampler System Mas-100 Nt Trade Information

  • Cash Advance (CA), Telegraphic Transfer (T/T), Cash in Advance (CID)

Product Description

ITEMCODE: 1091910001, HS CODE: 84798999

MAKE:MERCK MILLIPORE

  • MAS 100NT is a precision, independently validated acc. ISO 14698 portable microbial air sampler.to monitor air microbiology in cleanrooms Airflow 100 standard liters per minute, conforming to ISO 14698
  • Integrated mass flow sensor with temperature and pressure
  • compensation vertical airflow and isokinetic sampling speed prevent turbulence in the laminar airflow (smoke test) Operation with standard Petri dishes
  • Rechargeable battery, autonomy approx. 5,5 hours (33.000 L)
  • Housing made from anodized aluminum, perforated aluminum lid
  • (300x 0,6 mm) USB port, USB cable for Computer communication
  • Software and User manual
  • Qualification & Validation of  Instrument included



Precision Sampling and Compliance

The MAS-100 NT Air-sampler System delivers thorough microbiological air sampling with exact flow rate control and validated performance for ISO 14698 and GMP standards. Its sturdy stainless steel construction and digital interface ensure reliability for critical environments, while its automated correction features allow for consistent, accurate sample acquisition.


Efficient Operation and User-Friendly Features

Designed for portability and extended use, this sampler has a rechargeable NiMH battery pack offering up to 8 hours of runtime. The acoustic and optical alarm at cycle end, along with a clear digital display, keeps users constantly aware of system status. Easy-to-access controls simplify volume adjustments and data entry while ensuring operator safety and convenience.


Comprehensive Data Management and Connectivity

With memory for up to 100 samples, automated data logging, and RS-232 PC connectivity, users can seamlessly manage and export results for analysis or record keeping. Its multilingual interface supports broader accessibility, enabling users in diverse laboratory settings to navigate functions with ease.

FAQ's of Air-sampler System Mas-100 Nt:


Q: How does the MAS-100 NT ensure precise air sampling accuracy?

A: The MAS-100 NT employs electronic flow rate control and automatic correction, maintaining an accuracy of 2% at the set flow rate. Users can select volumes ranging from 1 to 2,000 liters, ensuring precise sample collection according to microbiological standards.

Q: What environments are suitable for using the MAS-100 NT Air-sampler System?

A: This air sampler is ideal for microbiological air monitoring in laboratories, cleanrooms, pharmaceutical manufacturing areas, and other controlled environments. Its stainless steel housing and compliance with EN ISO 14698 and GMP guidelines make it suitable for high-standard operational settings throughout India.

Q: When should the MAS-100 NT be calibrated, and what options are available?

A: Calibration can be performed manually or automatically, as recommended before each sampling campaign or after extended storage or transportation. This ensures continued accuracy and compliance with laboratory protocols.

Q: Where can the sampled data from the MAS-100 NT be accessed or exported?

A: With built-in memory for up to 100 samples, the MAS-100 NT allows users to access sampled data directly on its digital display. For extended analysis or record keeping, data can be exported to a PC via the RS-232 interface.

Q: What is the process for sampling air using agar plates with the MAS-100 NT?

A: Users install standard 90 mm agar plates in the autoclavable stainless steel sampling head. The sampler draws air through 400 perforations, depositing airborne microbes onto the agar surface for subsequent incubation and analysis.

Q: How does the MAS-100 NT benefit users in terms of portability and operational efficiency?

A: Weighing approximately 2 kg and powered by a rechargeable NiMH battery with up to 8 hours of runtime, the MAS-100 NT is highly portable. Its compact dimensions and easy-to-use controls streamline microbiological monitoring in various field or laboratory environments.