Product Description
Gated Integrators and Boxcar Averagers
SR240A 350 MHz preamplifier (4-channel)
Four independent channels
DC to 350 MHz bandwidth
1 ns rise and fall time
Voltage gain to 625
6.4 nV/Hz input noise
50 input and output impedance
3 ns overload recovery
Excellent phase linearity
The model SR240A 350 MHz Preamplifier is a 4-channel, DC-coupled instrument with a gain of 5 per channel. The amplifiers can be used independently or cascaded to provide gains of 5, 25, 125 or 625. The fast rise time, low noise, and DC accuracy of the SR240A make it the ideal instrument for use with photomultiplier tubes and photodiodes.
The SR240A preamp is useful for amplifying small signals to levels that can be processed by other boxcar system modules. Typically, a signal of at least a few millivolts is required at the input of the SR250. If your detector does not supply this signal level, the SR240A can be used in front of the SR250 to ensure sufficient signal amplitude.
SR240A Specifications
Amplifier channels 4
Inputs and outputs 50 , DC coupled
Bandwidth DC to 350 MHz (3 dB)
Rise/fall time 1 ns (single channel)
Voltage gain 5 per channel. Up to 4 channels can
be cascaded.
Input noise 6.4 nV/Hz
Operating range Inputs: 200 mV, Outputs: 1.0 V
Propagation delay 2.7 ns per channel
Recovery time 3 ns for a 10 overload
Input protection 50 V for <1 s
Output clamp 1.6 V
Output overload detect 1.3 V
Crosstalk 60 dB
Operating temperature 0 C to 40 C, non-condensing
Mechanical Single-width NIM module
Warranty One year parts and labor on defects
in materials and workmanship
High-Speed, Low-Noise AmplificationThe SR240A provides exceptional signal clarity with a noise figure below 4 nV/Hz at 1 kHz and a maximum gain of 100x. Its wide 350 MHz bandwidth accommodates a range of research and measurement applications, making it ideal for experiments where low distortion and high fidelity are critical.
Flexible and Robust DesignEquipped with four individually isolated channels, AC/DC coupling, and selectable input impedance, the SR240A adapts effortlessly to various signal sources. Its durable aluminum rack-mount chassis ensures longevity, while the option for both benchtop and rack installations maximizes laboratory flexibility.
FAQs of SR240A 350 MHz preamplifier (4-channel):
Q: How is the SR240A preamplifier typically used in laboratory or research settings?
A: The SR240A is designed for low-noise signal amplification, making it well-suited for scientific experiments that require precise measurement and high signal fidelity, such as physics, electronics, or engineering research.
Q: What process should I follow to switch between AC and DC coupling on the SR240A?
A: Switching between AC and DC coupling is straightforward and can be done using the front-panel controls. Simply select the desired coupling mode per channel, allowing for optimal signal conditioning based on your measurement requirements.
Q: When should I select 50 versus 1 M input impedance?
A: Choose 50 input impedance for high-frequency, low-impedance signal sources, and 1 M for voltage measurements from high-impedance devices. Switchable impedance allows compatibility with diverse equipment and experimental setups.
Q: Where can the SR240A be mounted or installed?
A: The SR240A is engineered for flexibility, supporting both rack-mount and benchtop installations. Its sturdy aluminum chassis ensures reliable performance whether integrated into laboratory racks or used as a standalone unit.
Q: What benefits does the high channel isolation of >80 dB provide?
A: High channel isolation minimizes crosstalk between the four channels, preserving the integrity of each signal. This feature is crucial for multi-channel measurements in environments with potential interference.
Q: How does the SR240A ensure low noise and signal accuracy during operation?
A: With its low input noise figure and optimized amplifier design, the SR240A maintains high signal fidelity and minimizes distortion. This guarantees accurate measurement results, even when amplifying weak signals.