08045815658
info@nationalsales.co
Change Language
LMA200PM Moisture Analyzer

LMA200PM Moisture Analyzer

Product Details:

  • Usage Laboratory & Industrial Moisture Analysis
  • Application Agriculture, Food, Chemical, Pharmaceutical
  • Display Type Backlit LCD
  • Function Moisture Content Determination
  • Connectivity Type Wired
  • IP Rating IP20
  • Features Halogen Heating, Fast Analysis
  • Click to view more
X

LMA200PM Moisture Analyzer Price And Quantity

  • 1 Number
  • 40°C to 199°C
  • Full
  • 10°C to 35°C, 80% RH max
  • Internal Memory up to 100 Programs
  • External Weight Calibration
  • English
  • 90 mm
  • Halogen Lamp
  • 0.01%
  • 1°C
  • 4 Pre-set & Customizable

LMA200PM Moisture Analyzer Product Specifications

  • Digital
  • Laboratory & Industrial Moisture Analysis
  • Stainless Steel and Plastic
  • Electric
  • Up to 200 g
  • 220V AC, 50/60Hz
  • 1 mg to 200 g
  • Agriculture, Food, Chemical, Pharmaceutical
  • Backlit LCD
  • LCD Graphic Display
  • 220 mm x 330 mm x 180 mm
  • Wired
  • Moisture Content Determination
  • Automatic
  • White & Grey
  • 0.01 g
  • Moisture Analyzer
  • RS232 Interface
  • Halogen Heating, Fast Analysis
  • IP20
  • 40°C to 199°C
  • Full
  • 10°C to 35°C, 80% RH max
  • Internal Memory up to 100 Programs
  • External Weight Calibration
  • English
  • 90 mm
  • Halogen Lamp
  • 0.01%
  • 1°C
  • 4 Pre-set & Customizable

Product Description

With microwave drying, the LMA200 moisture meter produces results up to 300 x faster than a drying oven for samples with high moisture content.

The built-in analytical balance ensures high precision in moisture analysis.


Overview

If thesample contains a high moisture content, microwave drying is the fastest andmost effective procedure (loss-on-drying) for heating samples. A sample isheated by absorption of microwave radiation. A built-in analytical weighingsystem measures the weight loss of a sample and determines the end point atwhich the sample has reached a constant weight. In addition, an air moisturesensor monitors the progress of a moisture analysis run, thus providing doublethe certainty to assure reliable results.

  • Can be used for liquid and pasty samples with a moisture content ranging from approx. 8 to 100%
  • Analysis time approx. 40 - 120 seconds (depends on type of sample and moisture content)
  • Easy two-key operation for routine moisture measurements
  • End-point determination: Fully automatic, by means of mass and moisture sensors; User-defined as loss of weight/unit of time for measurement; Timer mode
  • Built-in analytical weighing system with a capacity of 70 g and a resolution of 0.1 mg for weight values




Precision Moisture Analysis

Utilizing advanced halogen heating technology, the LMA200PM provides rapid and precise moisture measurement with readability down to 0.01%. Its capability to store up to 100 programs allows efficient workflow management in laboratory and industrial settings, ensuring repeatable data for critical quality assurance applications.


Versatile Applications and Features

Designed for use in agriculture, food processing, chemical, and pharmaceutical industries, this moisture analyzer supports both preset and custom drying programs. The digital LCD graphic display offers clear readings, and external calibration guarantees consistent accuracy. Its robust design is ideal for traders, exporters, importers, manufacturers, and suppliers across India.


Efficient Data Management and Connectivity

Internal memory storage and RS232 interface make data recording and transfer straightforward. The LMA200PM supports up to 100 customizable or preset analysis programs, while the backlit display enables easy operation in various laboratory environments. The IP20 rating ensures safe operation under standard conditions.

FAQ's of LMA200PM Moisture Analyzer:


Q: How does the LMA200PM Moisture Analyzer determine moisture content?

A: The LMA200PM uses halogen lamp heating to dry samples placed on a 90 mm pan. It measures the change in sample weight as moisture is evaporated, providing accurate moisture content readings in increments as small as 0.01%.

Q: What is the recommended operating environment for this analyzer?

A: For optimal accuracy and safety, the analyzer should be used within an ambient temperature range of 10C to 35C and a maximum relative humidity of 80%, in laboratory or industrial settings as specified.

Q: When should external weight calibration be performed?

A: External weight calibration should be conducted before beginning a new series of measurements or after relocation to ensure consistently precise results and maintain instrument accuracy.

Q: Where can the LMA200PM be utilized most effectively?

A: The analyzer is ideal for laboratories and industrial facilities involved in agriculture, food production, chemical and pharmaceutical analysis, and suitable for exporters, importers, manufacturers, suppliers, and traders in India.

Q: What are the benefits of customizable drying programs?

A: Customizable drying programs allow users to tailor analysis procedures to various sample types, optimizing accuracy and efficiency for specific industry needs or regulatory requirements.

Q: How is data stored and transferred from the analyzer?

A: Data can be stored internally for up to 100 programs and transferred via the RS232 wired interface, ensuring reliable documentation and facilitating integration into laboratory data systems.

Q: What is the process for moisture measurement using the LMA200PM?

A: To measure moisture, place a sample on the pan, select the appropriate drying program, and initiate the analysis. The instrument heats the sample, records weight changes, and displays the moisture content on the LCD graphic monitor.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Weighing Balances' category



Back to top