08045815658
info@nationalsales.co
Change Language
NACTZF  Wirewound 3 Zone Tube Furnaces to 1200C

NACTZF Wirewound 3 Zone Tube Furnaces to 1200C

5000 INR/Piece

Product Details:

  • Model No NACTZF
  • Core Components Heating elements, temperature controllers, ceramic tube support, thermocouples
  • Feature Multiple heating zones for uniform temperature distribution
  • Frequency 50/60 Hz
  • Accuracy 1C
  • Voltage 220V/240V/380V (as per order)
  • Capacity 3 zones (customized tube size, typical ID: 40150 mm, length: 3001200 mm)
  • Click to view more
X

NACTZF Wirewound 3 Zone Tube Furnaces to 1200C Price And Quantity

  • 1 Piece
  • 5000 INR/Piece

NACTZF Wirewound 3 Zone Tube Furnaces to 1200C Product Specifications

  • 220V/240V/380V (as per order)
  • Laboratory heat treatment, materials research, annealing, sintering, calcination
  • Digital PID controller with LED display
  • 3 zones (customized tube size, typical ID: 40150 mm, length: 3001200 mm)
  • 50/60 Hz
  • Multiple heating zones for uniform temperature distribution
  • Depends on tube size, e.g. 1000 x 450 x 500 mm
  • NACTZF
  • Heating elements, temperature controllers, ceramic tube support, thermocouples
  • 1C
  • Wirewound 3 Zone Tube Furnace
  • Electric
  • Semi-automatic (with programmable option)
  • Stainless steel exterior, ceramic fiber insulation
  • Ambient to 1200C
  • Up to 1200C
  • Approx. 60100 kg (varies by model and tube size)
  • High-purity ceramic fiber modules
  • 3-12 kW (depends on configuration and size)
  • O-ring or flange sealing, depends on tube design
  • Programmable digital controller with multiple segment ramp/soak
  • Individual PID control per zone for gradient and uniform heating
  • Suitable for inert, reducing, or oxidizing atmospheres
  • Alumina, Quartz, or SS (as per requirement)
  • Over-temperature protection, circuit breaker, fuse, door interlock
  • Up to 20C/min, adjustable
  • Kanthal (FeCrAl alloy) or MoSi2 (depending on temperature)
  • Gas inlet/outlet, vacuum flanges (optional)
  • Natural convection or fan-assisted (optional)
  • Central zone 2C uniformity

NACTZF Wirewound 3 Zone Tube Furnaces to 1200C Trade Information

  • 5-10 Piece Per Month
  • 6-8 Week

Product Description



Experience the prime efficiency of the NACTZF Wirewound 3 Zone Tube Furnaces (to 1200C), a trending solution for laboratories requiring stellar performance in heat treatment and materials research. This must-have unit is engineered with enviable safety and precision: individual PID controllers per zone, over-temperature protection, and programmable digital control. Adaptable to varying atmosphere needsinert, reducing, or oxidizingthese limited stock furnaces ensure gradient and uniform heating with 1C accuracy. Choose from alumina, quartz, or stainless steel tubes and benefit from multiple configuration options designed for enduring performance.

Unmatched Precision for Versatile Applications

The NACTZF Wirewound 3 Zone Tube Furnace delivers exceptional reliability for laboratory heat treatment, annealing, sintering, and calcination. Multiple heating zones enable precise control, making it ideal for both specific research protocols and general use, such as gradient thermal studies or material synthesis. The combination of customized tube sizes and digital segment programming offers a significant advantage in obtaining consistent, reproducible resultsempowering scientific innovation and advanced process development.


Efficient Order Processing & Global Logistics Reach

NACTZF furnaces are available for prompt order processing across the main domestic market in India and global exports. Units are carefully dispatched from major FOB ports, ensuring that each system is shipped securely and arrives on schedule. Meticulous logistics operations guarantee support to Europe, Asia, Africa, and the Americas. Whether you are a manufacturer, supplier, or research institution, efficient delivery and robust after-sales support make ordering and receiving your tube furnace straightforward and reliable.


FAQs of NACTZF Wirewound 3 Zone Tube Furnaces to 1200C:


Q: How does the 3 zone control improve furnace performance?

A: Individual PID controllers for each heating zone allow for precise temperature gradients and uniform heating, ensuring optimal conditions for complex materials research and heat treatment experiments.

Q: What are the safety features included in the NACTZF tube furnace?

A: The furnace is equipped with over-temperature protection, a circuit breaker, fuse, and a door interlock to provide comprehensive safeguards during operation.

Q: Where can these wirewound tube furnaces be shipped?

A: NACTZF tube furnaces can be dispatched both within India and to major international export markets, including Europe, Asia, Africa, and the Americas, through established logistics channels.

Q: What is the process for atmosphere control within the furnace?

A: These furnaces are compatible with inert, reducing, or oxidizing atmospheres, with customizable tube and sealing options to suit different experimental and processing needs.

Q: When should I choose Kanthal or MoSi2 heating elements?

A: Kanthal (FeCrAl alloy) elements are ideal for temperatures up to 1200C, while MoSi2 is recommended if your application demands higher operating temperatures and specific thermal characteristics.