Product Description
Semi-automatic Kjeldahl distillation unit for your analyses concerning different applications such as determining ammoniacal nitrogen, protein determination, nitrogen content (Kjeldahl or direct alkaline distillation), nitric nitrogen (after reduction/Devarda), phenols, volatile acids, cyanides and alcohol content.
Automated Operation
- Programmable water, sodium hydroxide addition and distillation time
- Selectable steam generation output level 10% 100%
- Auto removal of residues from sample tube
High Tech
- 3.5 inch color touch screen
- Library of 10 customizable methods
- Choice of 6 languages
- Mouse & printer USB connections
- No loss of nitrogen: distillate temperature stays below threshold
- Accurate dosing of reagents with high precision pumps
Outstanding Reliability
- Maintenance-free, resistant, patented steam generator
- Patented titanium condenser for unmatched performance
- Durable technopolymer splash head
- Chemically-resistant technopolymer housing
Operator Safety
- Lever operation simplifies tube insertion / removal (all sizes)
- Protection screen for distillation chamber
- Drip tray collects splashes
- Zero pressure steam generator
Ecology & Standards
- Performs to AOAC, EPA, DIN and ISO standards
- Incorporates TEMS technology*
Automated water supply control reduces consumption
*Saving Time, Energy, Money & Space | GENERAL FEATURES |
|
| Structure: | Corrosion-resistant technopolymer |
| Display: | 3.5" color touch screen |
| Time related to start for Devarda alloy analysis: | 0 99 min |
| Protocol library: | 10 customizable methods |
| Reproducibility (RSD): | 1 % |
| Recovery: | 99.5 % at nitrogen levels between 1 and 200 mg N |
| Detection Limit: | 0.1 mg N |
| Power: | 2100 W |
| Weight: | 26 kg / 57.3 lb |
| Dimensions (WxHxD): | 385x780x416 mm (15.2x30.7x16.4 in) |
|
|
| PERFORMANCE |
|
| Distillation time: | 4 minutes to collect 100 ml of distillate |
| Sodium hydroxide addition: | automatic |
| Water addition: | automatic |
| Sodium hydroxide volume: | 0 - 150 ml |
| Water volume: | 0 - 200 ml |
| Distillation time: | settable |
| Distillation residues removal: | automatic |
| Steam flow regulation: | from 10 to 100 % |
| Tap water consumption: | from 0,5 l/min at 15 C from 1 l/min at 30 C |
| Connections: | 2 x USB for printer, mouse |
Enhanced Laboratory Safety and EaseThis distillation unit features robust safety mechanisms including over-temperature cut-off, door interlocking, and leak protection, reducing operational risks in busy labs. Semi-automatic functions and programmable distillation times make the process straightforward, while integrated drainage and glassware facilitate smooth operation and cleanup.
Versatile Use Across IndustriesThe NACUDK 139 caters to diverse sectors such as agri-food, pharmaceuticals, and environmental labs, thanks to its wide nitrogen measurement range (0.1200 mg N) and compatibility with standard flask sizes. Its application is pivotal for routine nitrogen/protein estimation in research and quality control.
Accurate and Efficient DistillationDelivering reliable results, the unit achieves up to 0.5% accuracy for nitrogen estimation. Capable of processing up to 12 samples per hour, its high-performance ceramic or alloy heating system ensures consistent temperatures up to 450C, supporting rapid, repeatable ammonia steam distillations.
FAQs of NACUDK 139 Semi-Automatic Kjeldahl Distillation Unit:
Q: How does the NACUDK 139 Kjeldahl Distillation Unit operate in a laboratory setting?
A: The unit operates semi-automatically, allowing operators to manually add reagents and set programmable distillation times. It uses ammonia steam distillation to extract nitrogen from samples, with distillation complete in approximately 57 minutes per sample.
Q: What core safety features are integrated in the NACUDK 139 unit?
A: For enhanced safety, the unit includes an over-temperature cut-off, a door interlocking system to prevent access during operation, and leak protection, helping safeguard users from exposure to hazardous chemicals and overheating incidents.
Q: When should the cooling water system be monitored during operations?
A: Cooling water is crucial during every distillation cycle. The unit requires a steady supply of 400500 ml/min. Operators should ensure proper flow at all times to prevent overheating and optimize condensation efficiency during distillation.
Q: Where can the NACUDK 139 be utilized?
A: Its design supports versatile use across food, agricultural, environmental, and pharmaceutical laboratories where nitrogen or protein estimation is required via the Kjeldahl method.
Q: What is the process for handling spent reagents in this unit?
A: The NACUDK 139 features an integrated drainage system for the safe disposal of spent reagents post-distillation, simplifying clean-up and maintaining laboratory hygiene.
Q: What benefits does the digital display offer during process monitoring?
A: The digital display provides real-time monitoring of process parameters, assisting operators in maintaining precise control over temperature and operation time, thus enhancing accuracy and reproducibility of results.
Q: How does the semi-automatic feature improve workflow efficiency?
A: Semi-automatic operation reduces manual intervention, allowing faster sample throughputup to 812 samples per hourwhile maintaining consistent, accurate results. This boosts laboratory productivity and minimizes the potential for user error.