The Peak Scientific Fusion 1010 ingeniously provides Zero Nitrogen & Zero Air from one system and has a unique rapid restart control allowing it to be operational again after any power cut in a fraction of the time normally required. A huge benefit in areas where power supply is erratic.
Fusion 1010 delivers reliable high performance in the laboratory and comes with Peaks world class after sales service as standard.
TECHNICAL SPECIFICATIONS
Zero Nitrogen:
0.6 L/min @ 80 psi
Outlet CH4 Concentration (as Methane):
<0.1 ppm
Nitrogen Purity (as O2):
99.9995%
Zero Air:
1.5 L/min @ 60psi
Outlet CH4 Concentration (as Methane):
<0.1 ppm
Start Up Time to Purity:
3 hours
Particles >0.01micron:
None
Electrical Requirements:
230v +/- 10%, 50/ 60Hz, 4.5A
Dimensions (WxDxH):
51.1 x 76.2 x 71.2 cm / 20.1 x 30 x 28 ins
The FUSION 1010 offers ultra-high purity zero nitrogen (>99.999%) and zero air (<0.1 ppm THC), making it indispensable for critical laboratory tasks. Operating below 50 dB, it ensures minimal disruption in sensitive lab settings, blending performance with quiet efficiency.
Embodying robust construction with stainless steel and aluminium, this generator supports analytical instruments like GC detectors. Its compact form and internal 0.5L storage maximize space, while the digital display and automated functions simplify monitoring and control.
Delivering up to 500 ml/min gases, the Fusion 1010 maintains performance with just an annual service requirement. Integrated purification columns, filters, and compressor guarantee the supply of precise, contaminant-free gases required for advanced chemical analysis.
FAQs of FUSION 1010 ZERO NITROGEN & ZERO AIR GENERATOR:
Q: How is the purity of gases ensured in the FUSION 1010 ZERO NITROGEN & ZERO AIR GENERATOR?
A: The FUSION 1010 utilizes advanced purification columns and filtration systems, delivering zero nitrogen at >99.999% purity and zero air with less than 0.1 ppm THC to meet rigorous laboratory standards.
Q: What routine maintenance does the Fusion 1010 require and how often?
A: Thanks to its robust design, the Fusion 1010 requires minimal maintenance, with a recommended service interval of just 12 months to ensure ongoing accurate and reliable gas production.
Q: When should I use the FUSION 1010 generator in laboratory applications?
A: This generator is ideal for laboratories needing high-purity gases, especially with gas chromatography (GC) detectors, where contaminants can impact test accuracy and instrument longevity.
Q: Where can the FUSION 1010 ZERO NITROGEN & ZERO AIR GENERATOR be installed?
A: Its compact size (540mm x 410mm x 380mm) allows installation on laboratory benches or within analytical instrument workstations, regardless of the laboratorys spatial constraints.
Q: What is the process for generating both gases simultaneously?
A: The FUSION 1010 automatically produces both zero nitrogen and zero air up to 500 ml/min each. The fully automatic system manages output, ensuring both gases are available directly from the generator for immediate use.
Q: How does the Fusion 1010 benefit laboratory operations?
A: It provides uninterrupted access to ultra-pure gases without the need for frequent cylinder replacements. This reduces operational costs, saves time, and enhances data accuracy in sensitive analyses.
Q: What materials are used in constructing the Fusion 1010, and why?
A: The generator is constructed using stainless steel and aluminium, offering durability, resistance to corrosion, and suitability for challenging laboratory environments.