Automatic Kjeldahl Protein Analyzer

Automatic Kjeldahl Protein Analyzer

Product Details:

  • Power Source Electric
  • Measurement Range 0.1 mg to 200 mg Nitrogen
  • Frequency 50 Hz
  • Feature Automatic Operation, Inbuilt Fume Duct, Safety Door Lock, LCD Display, Overheating Protection
  • Temperature Range Ambient to 450C
  • Automation Grade Fully Automatic
  • Capacity 6 Digestion/Distillation Units
  • Click to view more
X

Automatic Kjeldahl Protein Analyzer Price And Quantity

  • 1 Piece
  • 5000 INR
  • 300 ml
  • 2 L/min during operation
  • Data Storage, Report Generation, USB Connectivity
  • Separate Waste Collection System
  • Over-temperature & Over-current Protection, Emergency Stop
  • PID Controlled Heating Elements
  • Efficient Water Cooling System
  • 5-8 Minutes
  • Automatic Calibration with Standard Solutions
  • 40 Samples/Day

Automatic Kjeldahl Protein Analyzer Product Specifications

  • AKPA-06
  • Stainless Steel Body, PTFE & Glass Components
  • Ambient to 450C
  • 6 Digestion/Distillation Units
  • Fully Automatic
  • Digestion Block, Distillation Unit, Reagent Dispenser, Cooling System
  • 0.1 mg N
  • 220V AC
  • Automatic Kjeldahl Protein Analyzer
  • Digital LCD Display
  • Approx. 60 kg
  • 540 x 410 x 700 mm
  • 50 Hz
  • Automatic Operation, Inbuilt Fume Duct, Safety Door Lock, LCD Display, Overheating Protection
  • Electric
  • 0.1 mg to 200 mg Nitrogen
  • Protein Analysis in Food, Feed, Agriculture, Chemical and Pharmaceutical Samples
  • 300 ml
  • 2 L/min during operation
  • Data Storage, Report Generation, USB Connectivity
  • Separate Waste Collection System
  • Over-temperature & Over-current Protection, Emergency Stop
  • PID Controlled Heating Elements
  • Efficient Water Cooling System
  • 5-8 Minutes
  • Automatic Calibration with Standard Solutions
  • 40 Samples/Day

Automatic Kjeldahl Protein Analyzer Trade Information

  • 10 Piece Per Month
  • 6-8 Week

Product Description

1. Adopt microcomputer controlling process;include manual mode andautomatic mode. Can be set and switchedaccording to user's need.2. Large array LCD display, touch key, easy tooperate.3. Automatically control distill, add water, controlwater level are cut off watersupply.4. Various security protections: digestive system security device,steamgenerator water shortage alarm, water level detection fault alarm.5. Stored operation procedure quantity: 2506. Instrument shell adopts specially made plastic spray steel. Workingareaadopts ABS anticorrosive board, Avoid chemical reagent corrosion andmechanical surface damage, acid proof and alkali proof.7. Once detected fault, controlling system will power offautomatically.Main technical parameters1. Measure variety: foodstuff, feedstuff, foods, dairy products, drink,soil, water, medicine,precipitate and chemical.2. Working mode: Automatic and manual (without titration)3. Storing data: 250 datum4. Measure range: 0.1mgN-200mgN (nitrogen content 0.1%-99%)5. Recovery rate: 99% (relative error, include digestion process)6. Repetition rate: relative standard deviation1%1NO.RS. 3,50,000/-7. Working hours: distillation time: 5-15 minutes, the user can setautomatically according todifferent samples.8. Voltage: AC 220V, 50Hz9. Cooling water consumption: distillation fraction 3L /min (watertemperature is less than 20degrees)10. Distillation fraction power supply: 1000W

Advanced Throughput and Precision

Designed for demanding environments, the Automatic Kjeldahl Protein Analyzer delivers high throughput with the capacity to handle up to 40 samples per day. The fully automatic system employs precision-controlled PID heating elements and efficient water cooling, ensuring reliable results with a measurement accuracy of 0.1 mg N across a range from 0.1 mg to 200 mg nitrogen.


User-Friendly and Safe Operation

Safety and usability are central to the analyzer's design. Advanced features such as over-temperature and over-current protection, an emergency stop button, a safety door lock, and an inbuilt fume duct provide robust operator protection. The digital LCD display, automatic calibration routines, and seamless USB connectivity ensure both ease of use and effective data management.


Efficient Waste Management and Sustainability

Integrating a separate waste collection system and using an efficient water cooling method at 2 L/min, the analyzer not only ensures clean laboratory operations but also supports sustainable practice. Its waste management design helps minimize environmental impact while facilitating routine laboratory workflows.

FAQ's of Automatic Kjeldahl Protein Analyzer:


Q: How does the Automatic Kjeldahl Protein Analyzer ensure accurate protein content measurements?

A: This analyzer uses an advanced PID-controlled heating system and efficient water cooling to tightly regulate sample processing conditions. Automatic calibration with standard solutions further guarantees a measurement accuracy of 0.1 mg N, providing highly reliable protein analysis across various sample types.

Q: What types of samples can be analyzed, and in which industries is this analyzer commonly used?

A: The Automatic Kjeldahl Protein Analyzer is suitable for food, feed, agriculture, chemical, and pharmaceutical samples. Its robust construction and automatic operation make it ideal for use in testing laboratories, research facilities, and quality control departments across these industries.

Q: When is maintenance required for the device, and how is waste managed?

A: Routine maintenance should be performed as recommended in the user guide, typically after each work cycle and as required by sample load. The separate waste collection system ensures that chemical residues are safely contained for proper disposal, maintaining laboratory hygiene and safety.

Q: Where can the Automatic Kjeldahl Protein Analyzer be installed effectively?

A: Its compact footprint (540 x 410 x 700 mm) allows for installation in standard laboratory spaces. The stainless steel, PTFE, and glass construction make it suitable for a variety of laboratory environments, including those handling corrosive chemicals or requiring strict safety standards.

Q: What is the process involved in sample analysis with this equipment?

A: Samples are placed in 300 ml tubes, then subjected to automated digestion and distillation within the unit. The system completes distillation in 5-8 minutes per sample, with calibration and data management fully automated. Reports are generated and data can be easily exported via USB.

Q: How does the analyzer benefit laboratory workflows and data management?

A: With automated operation, inbuilt safety features, and integrated software for data storage and report generation, laboratories benefit from increased efficiency, reduced risk of human error, streamlined workflows, and organized data records accessible via USB export.

Q: What safety mechanisms are included to protect users during operation?

A: Key safety features include over-temperature and over-current protection, an emergency stop button, a safety door lock, overheat protection, and an inbuilt fume duct. These measures ensure safe operation, even when handling potentially hazardous samples and reagents.