+919987787082
info@nationalsales.co
Change Language
NACCAF 16/38 (manual) - Coal Ash Fusibility Test Furnaces

NACCAF 16/38 (manual) - Coal Ash Fusibility Test Furnaces

Product Details:

X

NACCAF 16/38 (manual) - Coal Ash Fusibility Test Furnaces Price And Quantity

  • 1 Piece
  • 5000 INR

NACCAF 16/38 (manual) - Coal Ash Fusibility Test Furnaces Trade Information

  • 5-10 Piece piece Per Month
  • 6-8 Week

Product Description

The NACCAF 16/38 is designed to test coal ash fusibility according to the standards ASTM 1857-04 and BS ISO 540:2008.

The NACCAF 16/38 requires manual observation and recording of the transition points. In addition, a CAF furnace with automated digital image capture and archiving using Windows compatible software, the NACCAF DIGITAL, is available.

Standard Features

  • For determination of ash fusibility for coal ash (and optionally biomass or co-fired ash)
  • Suitable for testing to ASTM 1857-04 and BS ISO 540:2008 
  • Up to 12 samples may be tested simultaneously
  • Tests can be run up to 1600°C
  • Automated digital image capture and archiving using Windows compatible software
  • User defined temperature ramp and image capture rate
  • Sealed work-tube for use with fail-safe gas control mechanism for use with toxic and inflammable gas mixtures
  • The sliding and rotating door mechanism provides unrestricted access for sample loading
  • Supplied complete with image review software able to generate test reports of the transition temperatures
  • Supplied complete with sample holder, mounting tiles and loading tool
  • Specify the prefered gas mixture at the time of order
  • Programmed ramping to the test starting temperature

Options (specify these at time of order)

  • Control mechanisms for the following gas mixures
  • Reducing gas 60% (v/v) CO + 40% (v/v) CO2, Oxidising gas Air, Purge gas N2
  • Alternatively, Reducing gas 50% (v/v) H2 + 50% (v/v) CO2, Oxidising gasCO2, Purge gas CO2
  • Optional configuration for biomass ash or co-fired (biomass and coal mixture ashes)
  • CAF 16/38 Manual testing using obervation telescope
  • CAF 16/38 Reducing gas 60% (v/v) CO + 40% (v/v) CO2, Oxidising gas Air, Purge gas N2

Control Options

  • 301 Standard Controllers
  • 3216 Programmable Controllers
  • 3508 Programmable Controllers

Content may be subject to modifications or corrections

Enter Buying Requirement Details
Email Id
Mobile number

Other Products in 'HIGH TEMPERATURE APPLICATION SPECIFIC FURNACES' category



Back to top