Product Description
Fully automatic Kjeldahl distillation unit, with external titrator connection, for your analyses concerning different applications such as determining ammoniacal nitrogen, protein determination, nitrogen content (Kjeldahl or direct alkaline distillation), nitric nitrogen (after reduction/Devarda), phenols, volatile acids, cyanides and alcohol content.
Automated Operation
- Programmable boric acid, water, sodium hydroxide addition and distillation time
- Automatic processing in combination with a variety of titrators
- Selectable steam generation output level 10% 100%
- Auto removal of residues from titrator & sample tube
High Tech
- 3.5 inch color touch screen
- Library of 20 customizable methods
- Choice of 6 languages
- Mouse & printer connections
- No loss of nitrogen: distillate temperature stays below threshold
- Accurate dosing of reagents with high precision pumps
Versatile Data Handling
- Powerful archiving features
- Data exporting via USB to pen drive or PC in .xls format
- Data manipulation software can be user preferred
Outstanding Reliability
- Maintenance-free, resistant, patented steam generator
- Patented titanium condenser for unmatched performance
- Durable technopolymer splash head
- Chemically-resistant technopolymer housing
Operator Safety
- Lever operation simplifies tube insertion / removal (all sizes)
- Protection screen for distillation chamber
- Drip tray collects splashes
- Zero pressure steam generator
Ecology & Standards
- Performs to AOAC, EPA, DIN and ISO standards
- Incorporates TEMS technology*
Automated water supply control reduces consumption
*Saving Time, Energy, Money & Space | GENERAL FEATURES |
|
| Structure: | Corrosion-resistant technopolymer |
| Display: | 3.5" color touch screen |
| Time related to start for Devarda alloy analysis: | 0 99 min |
| Protocol library: | 20 customizable methods |
| Reproducibility (RSD): | 1 % |
| Recovery: | 99.5 % at nitrogen levels between 1 and 200 mg N |
| Detection Limit: | 0.1 mg N |
| Power: | 2100 W |
| Weight: | 27 kg / 59.5 lb |
| Dimensions (WxHxD): | 385x780x416 mm (15.2x30.7x16.4 in) |
|
|
| PERFORMANCE |
|
| Distillation time: | 3 minutes to collect 100 ml of distillate |
| Sodium hydroxide addition: | automatic |
| Water addition: | automatic |
| Boric acid addition: | automatic |
| Sodium hydroxide volume: | 0 - 150 ml |
| Water volume: | 0 - 200 ml |
| Boric acid volume: | 0 - 100 ml |
| Distillation time: | settable |
| Distillation residues removal: | automatic |
| Steam flow regulation: | from 10 to 100 % |
| Tap water consumption: | from 0,5 l/min at 15 C from 1 l/min at 30 C |
| Connections: | Ethernet, 2 x USB, RS232 and TTL for PC, printer, titrator, mouse, pen drive |
Cutting-Edge Automation for Precision AnalysisExperience increased efficiency and reliability in protein and nitrogen quantification with the fully automatic NACUDK 149 unit. Its programmable processes minimize manual intervention, maintaining consistency and improving safety throughout the entire Kjeldahl distillation protocol. The intuitive touch panel allows for straightforward parameter adjustments, ensuring optimal performance and high throughput.
Safe and Robust Chemical HandlingMade with an anti-corrosive, chemical-resistant PVC coated body and premium glassware, the NACUDK 149 ensures longevity even with stringent use. Multiple safety features, including over-temperature protection, automatic waste removal, and safety door interlocks, safeguard users and the laboratory environment during continuous operation.
Versatile Applications in Laboratory EnvironmentsWhether used in food quality labs, agricultural research, or chemical analysis facilities, this unit handles diverse sample types with capacity for up to 500 ml per run. The instruments precision meets ISO and CE standards, delivering accurate results essential for regulatory compliance and high-quality research.
FAQs of NACUDK 149 Automatic Kjeldahl Distillation Unit:
Q: How does the NACUDK 149 streamline the Kjeldahl distillation process?
A: The NACUDK 149 automates key steps such as water addition, programmable alkaline dosing, and steam distillation, reducing manual handling and human error. Its user-friendly color touch panel enables rapid parameter setup, and automated waste removal enhances overall workflow efficiency.
Q: What safety mechanisms are integrated into the unit?
A: The unit is equipped with over-temperature protection, a safety door lock system, and a steam leakage alarm, all designed to minimize risks during sample processing. These features help protect users and maintain a secure laboratory environment.
Q: When should I use the NACUDK 149 for sample analysis?
A: This unit is ideal whenever rapid, accurate protein or nitrogen quantification is required, such as in routine food, feed, soil, fertilizer, or chemical testing tasks. Its fast distillation time and capacity for multiple samples make it suitable for high-throughput laboratory operations.
Q: Where can the NACUDK 149 be effectively utilized?
A: The unit is suitable for a range of laboratory settings, including food quality control labs, agricultural research institutes, fertilizer testing facilities, and chemical manufacturing units, particularly those requiring compliance with ISO and CE standards.
Q: What benefits does the automatic distillation system provide over manual operation?
A: Automation ensures improved accuracy (1%), reproducibility, and reduced operator fatigue. The systems digital controls and safety interlocks also lower the chances of mishandling, delivering consistently reliable analytical results.
Q: How do I maintain and clean the NACUDK 149?
A: Routine maintenance involves checking the automated waste drain function, ensuring adequate cooling water flow, and routinely cleaning glassware with compatible solvents. The units chemical-resistant materials make it durable and easy to maintain.