NACPTC - Thermocouple Calibration Furnaces

NACPTC - Thermocouple Calibration Furnaces

5000 INR/Piece

Product Details:

  • Automation Grade Semi-Automatic
  • Temperature Range Ambient to 1200C
  • Capacity 2 to 6 Thermocouples per batch
  • Feature High Accuracy, Rapid Heating, Uniform Temperature Profile
  • Voltage 230 V AC
  • Power Source Electric Mains
  • Model No NACPTC-TCF-1200
  • Click to view more
X

NACPTC - Thermocouple Calibration Furnaces Price And Quantity

  • 5000 INR/Piece
  • 1 Piece

NACPTC - Thermocouple Calibration Furnaces Product Specifications

  • Laboratory Calibration Furnace
  • NACPTC-TCF-1200
  • 0C to 1200C
  • Thermocouple Calibration
  • PID Controller, Heating Elements, Thermal Insulation
  • 50 Hz
  • 1C
  • Semi-Automatic
  • Digital LED
  • Ambient to 1200C
  • 2 to 6 Thermocouples per batch
  • Stainless Steel, High-Temp Insulation
  • 500 x 300 x 350 mm
  • High Accuracy, Rapid Heating, Uniform Temperature Profile
  • 35 kg (approx.)
  • 230 V AC
  • Electric Mains
  • Front Opening Heat-resistant Door
  • 80% RH (Non-condensing)
  • Kanthal A1
  • RS-232/USB Optional
  • Natural Air Cooling
  • Traceable to National/International Standards
  • Over-temperature Protection, Current Limiting
  • Alumina Fiber/High Temperature Insulation
  • 10C/min to 20C/min
  • PID Microprocessor Based
  • Rectangular
  • 60 mm
  • 5C to 45C
  • J, K, T, E, N, R, S, B Types Supported
  • 2.5 kW

NACPTC - Thermocouple Calibration Furnaces Trade Information

  • 5-10 Piece Per Month
  • 6-8 Week

Product Description



The NACPTC - Thermocouple Calibration Furnace delivers exceptional performance with supreme accuracy, ensuring your calibration needs are met in a cost-effective manner. This popular laboratory furnace supports a resplendent range of thermocouple types (J, K, T, E, N, R, S, B) and offers rapid heating rates of 10C/min to 20C/min, reaching temperatures up to 1200C. Its robust alumina fiber chamber, advanced PID microprocessor controller, and built-in safety features guarantee reliable operation. With traceable calibration standards, digital LED display, and flexible connectivity, this product is the favored choice for exporters, importers, manufacturers, and suppliers seeking value and performance.

Applications, Suitability, and Operational Guidance

Used by calibration laboratories, research centers, and industrial quality control units, the NACPTC Thermocouple Calibration Furnace is suitable for precise temperature calibration of multiple thermocouple types. Users place thermocouples securely in the chamber and, following standard operating procedures, utilize the PID microprocessor controller to set target parameters. Its accuracy and ease of operation make it ideal for environments demanding high calibration reliability and repeatability.


Export Logistics, Packaging, and Payment Details

For reliable transportation to both domestic and international markets, NACPTC furnaces are packaged in robust, export-standard containerized cases to prevent transit damage. Serving a resplendent export market, our offerings depart from major Indian FOB ports, ensuring streamlined delivery logistics. Competitive outlay options are available, accommodating various payment terms such as advance payment, letter of credit, and telegraphic transfers, providing an accessible and secure purchase process for global clientele.


FAQs of NACPTC - Thermocouple Calibration Furnaces:


Q: How does the NACPTC Thermocouple Calibration Furnace ensure high accuracy during calibration?

A: The furnace features a PID microprocessor-based controller and Kanthal A1 heating elements, consistently maintaining uniform temperature profiles with an accuracy of 1C. Calibration is traceable to reputed national and international standards, ensuring dependable measurement results.

Q: What thermocouple types are supported by this calibration furnace?

A: This model accommodates popular thermocouple types such as J, K, T, E, N, R, S, and B, giving versatile compatibility for varied calibration needs within industrial and laboratory environments.

Q: Where can I use the NACPTC Thermocouple Calibration Furnace?

A: This furnace is well-suited for laboratory, research, and industrial quality assurance settings where precise thermocouple calibration is a requirement. It meets global export standards and can be integrated into facilities worldwide.

Q: What is the process for operating the calibration furnace?

A: Simply place the thermocouples in the alumina fiber chamber and use the digital LED interface and PID controller to set your required parameters. The front opening heat-resistant door ensures safe and convenient loading and monitoring.

Q: What benefit does the natural air cooling system provide?

A: Natural air cooling promotes gradual, uniform cooling, minimizing thermal shock to both the furnace chamber and the thermocouples being calibrated. This enhances equipment longevity and ensures consistent calibration outcomes.

Tell us about your requirement