Product Description
SEMI AUTOMATIC FLASH POINT APPARATUS WITH ALL FEATURES
AUTOMATIC EXCEPT THE FLASH & FIRE DETECTION AS PER ASTM D
92,IP 36 , IS 1448 9P-69).IT CONSIST TEMP. IS CONTROLLED BY DIGITAL THYRISTOR VOLTAGE REGULATOR , TEMP. IS INDICATED BY DIGITAL TEMP. INDICATOR , AUTOMATIC IGNITION OF THE FLAME WITH AUTOMATIC TO & FRO MOVEMENT ABOVE THE CUP WITH REMOTE. NO NEED TO TOUCH THE INSTRUMENT EXCEPT YOU JUST HAVE TO OBSERVE THE FLASH POINT AND FIRE POINT. Precision Measurement with Safety FirstThe Semi Automatic Flash Point Apparatus offers precise temperature readings for identifying flash points of flammable liquids. Featuring an advanced microprocessor-based system, it ensures consistent results and safeguards users with built-in automatic overheat cut-off. Its variable, digitally controlled stirring delivers accurate mixing for each test, while the digital LED display enables effortless monitoring.
Robust Construction for Long-Term UseEngineered with a rust-proof mild steel body and finished with powder coating, the apparatus resists corrosion even in demanding environments. The equipments compact footprint and approximate weight of 13 kg allow convenient placement and easy handling. Its design meets international standards, ensuring reliability in every testing scenario.
Versatile Compatibility and ComplianceThis apparatus can perform both open and closed cup testing, allowing compliance with ASTM D92 and IS 1448 (P:69) test methods. With compatibility for electric and gas flame ignition sources, and support for digital readouts, it enables laboratories to conduct diverse flash point tests on up to 60 ml samples efficiently and with confidence.
FAQs of SEMI AUTOMATIC FLASH POINT APPARATUS :
Q: How does the Semi Automatic Flash Point Apparatus deliver accurate measurement results?
A: The apparatus utilizes a microprocessor-based control system, variable digital stirring, and precise temperature sensing, ensuring each test meets the required standards. Its digital LED display provides direct, reliable temperature readings up to 400C with an accuracy of 1C.
Q: What advantages does the automatic cutoff feature provide during testing?
A: The automatic cutoff function activates if the system overheats, protecting the user and apparatus. This feature prevents potential accidents and ensures long-term durability by automatically stopping operations in abnormal conditions.
Q: When should I use the open cup versus the closed cup test method?
A: Open cup tests are suitable for substances with expected higher flash points, while closed cup testing is preferred for materials with lower flash points or when more precise control of test conditions is required. The apparatus supports both methods for comprehensive analysis.
Q: Where is the Semi Automatic Flash Point Apparatus most effectively used?
A: This equipment is ideal for chemical, petrochemical, and materials testing laboratories, as well as quality control settings across research, manufacturing, and trade industries throughout India.
Q: What is the process of using this apparatus for a flash point test?
A: First, prepare a 60 ml sample in the corrosion-resistant test cup. Select the desired test method (open or closed cup) and ignition source (electric or gas flame). Set the temperature and stirring speed via the digital interface, then monitor results on the LED display. Safety cutoffs operate automatically if temperature limits are approached.
Q: How does the powder-coated finish benefit the equipment in laboratory environments?
A: The powder-coated, rust-proof mild steel body provides robust resistance to chemicals and corrosion, ensuring the apparatus remains reliable and presentable even after prolonged use in high-traffic labs.