Product Description
Lanthanide Analysis Using a Resolve C18 Radial-Pak Cartridge
Description Dimension Size Size Part No.
Resolve C18 * 8 x 100 mm 5 m 90 WAT084624
8 x 10 Cartridge Holder WAT082887
* Requires 8 x 10 Cartridge Holder
Consistent Performance and High Separation EfficiencyEngineered for reliability, Waters HPLC Columns provide stable packing and cylindrical design for robust operations. The fully end-capped C18 phase and silica-based material ensure sharp peak resolution, even at a maximum temperature of 60C, and within a pH range of 2 to 8. This facilitates reproducible outcomes for mix analyses, from pharmaceuticals to chemicals.
Flexible Applications and Easy IntegrationThese columns are compatible with fingetight fittings, simplifying connection to various HPLC systems. Their USP L1 phase type makes them suitable for a broad spectrum of reverse-phase separations. Both exporters and suppliers across India benefit from the columns adaptabilitysupporting both manual and automated chromatographic setups.
FAQs of Waters HPLC Columns:
Q: How do I properly install a Waters HPLC Column using fingetight fittings?
A: To install the column, connect it securely using standard fingetight fittings compatible with most HPLC systems. Ensure the flow direction matches the column markings, and tighten the fittings evenly to prevent leaks. Avoid over-tightening, as it may damage the stainless steel connections or silica packing.
Q: What types of samples can be analyzed using a Waters C18 reverse-phase column?
A: The fully end-capped C18 (Octadecyl) reverse phase column is ideal for a wide range of samples, including pharmaceuticals, environmental compounds, food additives, and chemicals requiring high-resolution separation in HPLC analysis.
Q: When should I replace the Waters HPLC Column for optimal performance?
A: Columns typically last up to five years if handled according to the manufacturers guidelines, but replacement is recommended if there is a notable drop in separation efficiency, increased backpressure, or inconsistent results despite routine maintenance.
Q: Where can Waters HPLC Columns be sourced in India for laboratory use?
A: Waters HPLC Columns are available through various channels in India, including authorized exporters, manufacturers, suppliers, and traders specializing in chromatography equipment.
Q: What process ensures consistent results with this HPLC Column?
A: Consistent results are supported by stable silica-based packing and stringent manufacturing controls per USP and ISO 17025 standards. Routine system calibration, proper mobile phase preparation, and regular equipment maintenance also contribute to reliability.
Q: How does using a fully end-capped C18 column benefit my HPLC application?
A: A fully end-capped C18 column exhibits reduced silanol activity, minimizing unwanted secondary interactions and enhancing peak shape for polar and nonpolar analytes. This results in improved reproducibility and higher separation efficiency.