08045815658
info@nationalsales.co
Change Language
High-Strength-Silica (HSS) HPLC Analytical Columns

High-Strength-Silica (HSS) HPLC Analytical Columns

10000 INR/Piece

Product Details:

  • Features High strength durability, excellent batch-to-batch reproducibility, high chemical stability
  • Shape Cylinder
  • Control Type Manual or system-controlled
  • Accuracy High Separation Efficiency
  • Temperature Resistance Up to 60C recommended
  • Type HPLC Analytical Column
  • Dimension (L*W*H) 150 mm x 4.6 mm I.D.
  • Click to view more
X

High-Strength-Silica (HSS) HPLC Analytical Columns Price And Quantity

  • 3 Piece
  • 10000 INR/Piece

High-Strength-Silica (HSS) HPLC Analytical Columns Product Specifications

  • Cylinder
  • High Strength Silica (HSS)
  • HPLC Analytical Column
  • Up to 60C recommended
  • High Separation Efficiency
  • Manual or system-controlled
  • Stainless Steel Housing, Silica Packing
  • Analytical and Research Applications in HPLC
  • High strength durability, excellent batch-to-batch reproducibility, high chemical stability
  • Chromatography Column
  • 150 mm x 4.6 mm I.D.

High-Strength-Silica (HSS) HPLC Analytical Columns Trade Information

  • 3-4 Piece Per Day
  • 3-4 Week

Product Description



Experience the ace performance of our New Release High-Strength-Silica (HSS) HPLC Analytical Columns, designed to deliver perfect separation and unmatched reliability. Personalise your research with options in USP Classification L1 (C18) or L7 (C8) to suit diverse applications. With a particle size of 3.5 m and pore size of 100 , these gorgeous columns ensure high durability, chemical stability, and accuracy up to 6000 psi. Grab Yours now to advance your analytical and research capabilitiesperfect for UV, PDA, MS, RI, and Fluorescence detectors. High strength, fully endcapped, and ready for any challenge!

Suitable Use, Application Method & Distinct Features

High-Strength-Silica (HSS) HPLC Analytical Columns are ideal for precise analytical and research purposes in laboratories. Suitable for use in chromatography systems equipped with standard 10-32 fittings, they are compatible with a wide range of detectors including UV, PDA, and MS. The columns are manually or system-controlled, providing high separation efficiency, excellent durability, and remarkable chemical stability. Their fully endcapped, high-purity silica ensures consistent performance and exceptional reproducibility for researchers in pharmaceuticals, food safety, and environmental labs.


Payment Terms & Market Reach: Your Order, Anywhere

Order processing is straightforward, with quotations prepared promptly following your inquiry. Payment terms are flexible and designed to suit both domestic clients across India and international buyers, ensuring smooth order completion. We serve the main domestic market throughout India, while also exporting to global research hubs. Our commitment to efficient order handling and timely delivery makes us a trusted exporter, importer, manufacturer, supplier, and trader. Choose us for a hassle-free procurement process and reliable, top-tier HSS HPLC Analytical Columns.


FAQs of High-Strength-Silica (HSS) HPLC Analytical Columns:


Q: How do I select the right USP Classification (L1 or L7) variant for my application?

A: To choose the appropriate USP Classification, identify whether your method requires C18 (L1) or C8 (L7) characteristics. L1 (C18) offers higher hydrophobicity, ideal for most reversed-phase separations, while L7 (C8) suits mid-polar compounds or shorter retention times.

Q: What is the typical process for ordering and receiving High-Strength-Silica HPLC Analytical Columns?

A: Begin by requesting a quotation based on your requirements. Once confirmed, we process the order and arrange shipment after payment. Order completion and delivery times are communicated clearly to ensure a smooth transaction, domestically and internationally.

Q: Where can these HPLC Analytical Columns be used?

A: These columns are suitable for analytical laboratories across pharmaceuticals, food safety, environmental analysis, and research institutions, both in India and globally, wherever silica-based HPLC separation is required.

Q: When should I replace my HSS HPLC Column for optimal performance?

A: Replace the column if you notice loss of resolution, pressure anomalies, or increased run times. Unopened columns have a shelf life of 35 years; replacement intervals depend on usage frequency and sample matrix.

Q: What are the benefits of using fully endcapped, high-strength silica columns?

A: Fully endcapped columns provide minimized silanol activity, delivering more consistent retention, better peak shapes, and improved batch-to-batch reproducibility, essential for high-efficiency analytical work.

Q: How does the columns high-pressure tolerance and temperature resistance enhance my workflow?

A: With a maximum pressure tolerance of 6000 psi and stable operation up to 60C, these columns accommodate high-throughput methods and challenging separations, supporting robust and efficient laboratory performance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'HPLC Columns' category



Back to top