Product Description
| SPECIFICATION: | Range | EC | 0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm (actual EC) |
| TDS | 0.00 to 14.99 mg/L (ppm); 15.0 to 149.9 mg/L (ppm); 150 to 1499 mg/L (ppm); 1.50 to 14.99 g/L (ppt); 15.0 to 100.0 g/L (ppt); up to 400.0 g/L (actual TDS), with 0.80 conversion factor |
| NaCl | 0.0 to 400.0% |
| Temperature | -20.0 to 120.0°C | | Resolution | EC | 0.01 µS/cm; 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm |
| TDS | 0.01 mg/L; 0.1 mg/L; 1 mg/L; 0.01 g/L; 0.1 g/L |
| NaCl | 0.1% |
| Temperature | 0.1°C | | Accuracy @ 25°C | EC | ±1% of reading ± (0.05 µS/cm or 1 digit) |
| TDS | ±1% of reading ± (0.03 mg/L or 1 digit) |
| NaCl | ±1% of reading |
| Temperature | ±0.4°C | | Calibration | EC | automatic, one point with six memorized values (84, 1413, 5000, 12880, 80000, 111800 µS/cm) |
| NaCl | one point, with HI 7037 calibration solution |
| Temperature | two point, at 0 and 50°C | | Temperature Compensation | | automatic or manual from -20.0 to 120.0°C | | Temperature Coefficient | | selectable from 0.00 to 6.00%/°C (EC and TDS only) | | TDS Factor | | selectable from 0.40 to 0.80 (default value: 0.50) | | Probe | | HI 76310 platinum, four ring conductivity/TDS probe with internal temperature sensor and 1 m (3.3') cable (included) | | PC Connection | | opto-isolated USB | | Logging | | log on demand, 500 samples | | Auto-off | | after five minutes of non-use (can be disabled) | | Power Supply | | 12 VDC adapter (included) | | Environment | | 0 to 50°C (32 to 122°F); RH max 95% | | Dimensions | | 235 x 218 x 108 mm (9.2 x 8.5 x 4.2”) | | Weight | | 1.3 kg (2.9 lbs.) | |
FEATURE: - Autoranging; The EC and TDS scales are autoranging. The meter automatically sets the scale with the highest possible resolution.
- Manual range selection and range lock
- Four ring potentiometric conductivity probe with internal temperature sensor
- Automatic (ATC), manual (MTC) or no temperature compensation (NoTC)
- GLP features
- Log-on-demand up to 500 records
- PC compatible via USB
|
Exceptional Accuracy and Ease of UseThe TEMPRETURE PH METER delivers precise pH (0.1) and temperature (0.5C) readings with impressive resolution, making it invaluable for routine testing in laboratories and industrial environments. The manual control mode allows users the flexibility to tailor measurements to specific needs, while the backlit display ensures clear data visibility, even in dim settings.
Reliable Portability and DurabilityWith a compact form factor and ergonomic grip, this handheld meter is engineered for both field and laboratory applications. Its waterproof IP65 rating and RoHS compliance provide dependable operation in varied environments, ensuring longevity and consistent performance during rigorous use.
FAQs of TEMPRETURE PH METER:
Q: How do I replace the electrode in the TEMPRETURE PH METER?
A: To replace the glass electrode, carefully detach it from the meter following the instructions in the user manual. Ensure the new electrode is compatible and securely connect it, then calibrate the device before use for optimal performance.
Q: What types of samples can I measure with this meter?
A: This meter is designed specifically for aqueous solutions. It is suitable for measuring pH and temperature in water-based samples used in laboratories, industrial processes, and field testing scenarios.
Q: When should I calibrate my TEMPRETURE PH METER?
A: It is recommended to calibrate the pH meter before each session of intensive measurement or whenever precise accuracy is required. Regular calibration ensures the continued reliability of readings, especially after replacing the electrode.
Q: Where can this handheld meter be used?
A: The TEMPRETURE PH METER is versatile enough for use in laboratories, industrial environments, and field locations. Its portable design and waterproof rating make it suitable for a diverse range of settings.
Q: What is the process for obtaining accurate readings?
A: Begin by turning on the meter and immersing the electrode in the liquid sample. Wait for the reading to stabilize (typically within 2 seconds), and read the pH and temperature values directly from the digital LCD. For best results, keep the electrode clean and calibrated.
Q: How can the automatic temperature compensation feature benefit users?
A: Automatic temperature compensation ensures that pH readings remain accurate across varying sample temperatures, eliminating the need for manual calculations and reducing the risk of errors in measurement results.